Appendix 1

Guidance Notes for compliance with the Code of Practice

The following notes are given to assist in meeting the requirements of the code and represent a minimum standard.

Each note is preceded with the number of the relevant Article from the Code. The reference number is preceded with the letter "A" to distinguish the Note from the actual Article).

A1.1 Testing.

Before any engine is run in public it must be shown that it is capable of sustaining the stresses arising from forces generated in the engine. These forces will include:-

* Centrifugal forces arising from the high rotational speeds of the compressor and turbine.

* Gyroscopic forces on the rotor assembly arising from changes in direction of motion of the engine.

* Bending forces on the rotor shaft as the critical speed is approached.

As an absolute minimum an engine must demonstrate that it can survive, without damage, three consecutive runs each of 10 minutes duration at continuous maximum rated power.

A1.2 Certification of Material Specification

It is recommended that materials intended for highly stressed components be obtained complete with a certificate confirming the material specification and any process (such as heat treatment etc.,) to which the material has been subjected.

A2.2 Over-speed protection

The engine and its systems should be designed and constructed such that the rotational speed cannot exceed the maximum safe limit. This may be achieved by the following:-

A2.2.1
The fuel system is permanently restricted to limit the fuel flow to a safe value.

A2.2.2
Fuel pump motor battery voltage is limited by the number of cells in the battery such that the pump output will not exceed the engine's maximum safe demand if the electronic control fails and continuously applies full battery voltage to the pump motor.

A2.2.3
The fuel system incorporates a pressure relief valve set to limit the fuel pressure so that fuel flow cannot exceed the maximum safe value. The relief system must contain the fuel and return it to the suction side of the pump or to the tank.

A2.3 Under-speed protection.

Engine fires can result from the engine losing speed, as a result of mechanical problems, to a level such that the consequent exhaust temperatures will have risen too high. Also, because of the reduced airflow arising from the loss of rotational speed, combustion chamber performance will deteriorate and fuel will begin to burn outside of the combustion chamber. Under these circumstances the fuel must be shut off to avoid a fire. The operator of a remotely controlled engine may not, under certain conditions, detect the under-speed condition and may therefore not react in time to prevent a fire.

Hence consideration should be given to a control system whereby an engine under-speed condition causes the fuel to be shut off.

A pressure switch sensing the compressor diffuser discharge pressure and arranged to be open circuit whenever the pressure falls below the engines minimum safe operating pressure will provide suitable protection if connected in series with the pump motor. An manual switch with mechanical spring bias to the open circuit condition, connected in parallel with the pressure switch, would be required to override to pressure switch during engine starting.

A2.4 Over-temperature protection.

Over-temperature protection by electronic means should not be considered a substitute for inherent over-temperature prevention. However, at the engine test and development stage there will be benefits in incorporating some form of active temperature control whereby the fuel flow is reduced whenever the exhaust gas temperature exceeds acceptable limits.

A2.6 & A2.7 Remote Control and Emergency Fuel Shut-off Systems

There should be some means of remotely isolating the fuel supply in an emergency. If the engine is being operated under radio control the isolating valve should be operated by a servo assigned to a separate control channel independent of the throttle. This servo channel should also be arranged to close the valve if the radio link fails, (necessitating a radio system with fail-safe facilities). There may be an advantage in having a short time delay before closing the valve on radio failure to prevent unnecessary stopping of the engine during very short term interruptions in the radio signal.

The servo and valve must be linked so that the valve can only be moved to the closed position by the servo. Once closed the valve must not be able to be opened by the servo. The valve should only be able to be opened manually and should remain closed except when the engine is about to be started.

In the event of the operator initiating a shut-down, or the radio entering the fail-safe mode the valve would shut off the fuel, stopping the engine. The fuel pump must not deliver any more fuel until the valve is manually reset. The servo must not be allowed to open the valve by operator command or if the radio signal is regained as the pump would once more deliver fuel. This, at the least, would saturate the model with unburnt fuel, but worse, could result in a fire.

A suitable linkage between servo and valve would be arranged to have "slack" or lost motion equal to the amount of motion needed to move the valve from the open to the closed position. Thus the servo would only be able to close the valve, which could only then be opened by hand after the servo had been returned to the "open" position.

Under no circumstances should the failsafe of a PCM receiver fitted to a turbine powered model be left in the default mode. Depending on the make of equipment in use this may result in the throttle either remaining at the last known throttle setting or going to half power. It must instead be programmed to cut the engine altogether, by setting the throttle to the minimum and operating the fuel shutoff valve.

Please note that, depending on the configuration of receiver, switch and battery, the failsafe programming may be lost when the battery is disconnected. The setting should therefore be checked before each engine start. When switching from a PPM receiver to a PCM one it is important to note that, although you ECU or speed controller may cut the engine if the PPM receiver loses signal, the PCM failsafe will mask this function.

A3.4 Pressure testing of fuel systems.

An acceptable test would be to block the system at the entry point to the engine and run the fuel pump motor directly connected to a freshly fully charged battery with the electronic speed control system disconnected. This test will apply the maximum available voltage to the pump motor and represents the worst case of short circuit failure of the electronic control. The number of cells used and their nominal capacity should be recorded and means taken to ensure that these values are not exceeded. For example the battery compartment cover could carry a notice stating the maximum number of cells, the nominal battery voltage and the cells' nominal capacity.

Limiting the maximum permissible voltage or number of cells used in the fuel system power supply will also contribute to preventing the gas turbine from being operated above its maximum permissible speed.

A3.5 & A4.8 Fuel and Oil Systems Materials

Materials containing the fuel and oil must be suitable for these duties. It is essential to determine the long-term effects of exposure to fuels and oils. Some flexible plastic materials become brittle after exposure to typical gas turbine liquid fuels. Such embrittlement could lead to leaks or fractures in the fuel system. It is a simple matter to soak a material sample in the fuel or oil for a prolonged period and then to test the material for flexibility and dimensional stability.

Fuel and oil lines can also be exposed to elevated temperatures in the vicinity of the engine so the convenience of flexible plastic tubing may have to be sacrificed and metal tube used in the final connection to the engine.

Gas fuelled engines present an additional problem in that the gas will be stored in the fuel tank initially in a liquefied state. The fuel system materials must be suitable for the very low temperatures created by evaporation of the fuel to the gaseous state while on route to the combustion chamber. This problem could also apply to the gas starting system of liquid fuelled engines.

A3.6 Starting System Fuel Lines

Liquid fuelled engines which are started on gas present a potential hazard if the starter gas system is integrated with the main (liquid) fuel system. Such integrated systems allow the risk of starter gas invading the liquid fuel tank where it would present a greater hazard than that expected of liquid fuel.

It has also been found that fuel manifolds intended for liquid fuel can become overheated and damaged if subjected to prolonged exposure to gaseous fuels. This arises because the manifold would normally be cooled by the liquid fuel.

A3.7 Pressurising fuel tanks

For liquid fuelled engines it is recommended that the fuel pressure is raised and controlled by a motorised pump which draws the fuel from a tank which is not significantly pressurised. There are systems under development which have eliminated the motorised pump and in its place use pressurisation of the fuel tank. When such systems have been safely developed guidelines will be provided.

A3.10 & A4.6 Filtration and Cleanliness.

A totally clean zone should be maintained, for both fuel and oil, by the following means:

a) Most importantly start with clinically clean fuel tanks, pump and pipework and filter all fuel stocks - even fresh paraffin can be very dirty.
b) Fit a filter to the discharge of the storage container, this should make the tank a clean zone.
c) Fit a filter on the fuel tank overflow pipe, as the air coming in to replace the fuel is probably dirtier than the fuel in the storage container.
d) A filter can, optionally, be fitted between tank and fuel pump but it must be cleaned regularly and it can be a significant source of leakage. Filters on the section between pump and turbine are subject to higher pressures increasing the possibility of a leak.
e) Plastic bodied fuel pumps are not recommended as they can shed plastic particles, which will block the vaporiser/fuel jets.

The same principles apply to the oil system:

a) Filter the oil when filling the tank.
b) Fit a filter in the oil tank pressurisation pipe, as the air from the engine could be dirty.
c) Fit a filter in the air path to the bearings. Very fine bronze gauze will to keep out the larger particles; do not use a too fine a filter as the air flow may be impeded.

A4.5 Lubricating Oil Flow Rates.

The very high speeds to which small gas turbine shaft bearings are subjected impose quite severe requirements on the lubrication system. In general the oil flow will have to be restricted to very low rates. Excessive oil flow will actually result in early failure of the bearings, probably arising from hydraulic effects causing rolling elements to lock-up and skid with consequent high wear rates.

Oil flow rates should be set to the designer's or manufacturer's recommendations and are usually measured with the engine running at full power.

Flow rates of the order of 0.3 millilitres/minute are typical for engines of the Schreckling FD3/64 class. Excess oil flow will result in randomly occurring flaring in the exhaust stream, sometimes accompanied by a "fluffing" sound, as the excess oil is ignited.

A4.10 Confirmation of Oil Flow

Means should be provided which allow the oil flow to be verified. A transparent section of line will allow oil flow to be seen as the system primes but flow will not be obvious when air has been purged from the line. Also flow rates, when correctly set, may be so small that it is difficult to register a fall in the level of oil in the reservoir, however it may be possible to determine a difference in the oil level before and after a run.

A5.3 Foreign Object Damage

Foreign matter sucked into an engine presents a particular hazard. The result is known throughout the aviation world as FOD (Foreign Object Damage). Any loose articles in the fuselage will almost certainly be "discovered" by the engine and, with the same degree of certainty, will result in FOD. Additionally, particles thrown up by aircraft landing gear can be sucked into the engine. The probability of this is especially high on aircraft where the nose leg is located forward of the air intake or where the gear bays are not sealed off to the inside of the fuselage. Water thrown up by the aircraft as it taxies, takes off or lands through puddles on the runway can also result in FOD.

A5.6 Protection from High Temperatures

Some systems will inevitably be exposed to high temperatures. Where this occurs the materials must be suitable for high temperature use or suitable thermal insulation used to provide protection. For example exhaust gas temperature thermo-couple probes should be of Inconel sheathed mineral insulated construction and of sufficient length to place the connecting wires away from the exhaust heat.

Exhaust ducts will have to both withstand the temperature of the exhaust gases and protect the surrounding structure from the heat from the duct itself. It will not be sufficient to install a heat resistant metal duct without also providing some insulation on the outside of the ductwork. The necessary insulation can take the form of conventional heat-resistant insulation such as lightweight ceramic fibre or could be provided by a cooling flow of air. In the air-cooled solution consideration must be given to protection against loss of the air flow.

Heat reflective materials can be very useful in protecting the structure from exhaust heat.

There may be some benefit in treating wooden structures with flame retarding agents which can be obtained in aerosol spray cans. The effect of such agents on the strength of the structure and on surface finishes should be determined on test pieces.

A6.1.1 Dealing with Fire.

(In respect of dealing with a fire in a model aircraft which is powered by a gas turbine.)

A6.1.1.a Training.

All persons assigned to fire-fighting must familiarise themselves with the use of the particular fire extinguisher to be employed by careful study of the extinguisher manufacturer's written instructions and procedures.

The fire-fighters should also be instructed by the operator of the gas turbine as to the most effective ways of dealing with a fire. For instance, the fire-fighters should be made aware of any specific access points on the model through which to direct extinguishant.

The operator of the gas turbine must retain authority over the fire-fighters to prevent the unnecessary discharge of fire extinguishers, for example during a "wet-start" which the operator is able to bring under control.

A6.1.1.b Risks to Fire-fighters.

All potential fire-fighters must be made aware of the specific hazards associated with any particular model. For instance if the fuel involved is a gas contained under pressure there is a risk of the pressure vessel exploding in a fire. Only in the very early stages of such a fire would it be safe to approach and attempt to fight the fire.

Fires involving liquid hydrocarbon fuels which are not normally contained under pressure present a lesser risk but fire-fighters must allow for the circumstance of the fuel vaporising in the heat of the fire, causing the container to become pressurised and subsequently exploding.

A6.1.1.c Foam extinguishers.

Foam extinguishers are not recommended for model aircraft fire-fighting because of the mess and potential damage resulting from their use. (In the UK. the containers of foam extinguishers are currently cream in colour).

A6.1.1.d Dry Powder extinguishers.

Dry Powder extinguishers are not recommended for model aircraft fire-fighting because of the mess and potential damage resulting from their use. (In the UK. the containers of Dry Powder extinguishers are currently blue in colour).

A6.1.1.e Halon or BCF extinguishers.

Halon or BCF extinguishers containing at least 1.5 kg of extinguishant are recommended for model aircraft fire- fighting. (In the UK. the containers of Halon or BCF extinguishers are currently green in colour).

A6.1.1.f Carbon Dioxide (CO2) extinguishers.

CO2 extinguishers containing at least 2.5 kg of extinguishant are recommended for model aircraft fire-fighting. (In the UK. the containers of CO2 extinguishers are predominately black in colour).

A6.1.1.g Colour coding of fire extinguishers.

It is understood that all fire extinguishers will in the future be coloured red.

A6.1.1.h NEVER USE A WATER JET on a liquid fuel fire.

A6.1.1.i On-board extinguishers.

In the event of a crash of a gas turbine powered model aircraft it is extremely likely that the crash site will be some distance from the location of the fire-crew. Also it is possible for a fire to develop while the model is airborne and a landing made some distance from the fire-crew. Therefore consideration should be given to arranging for the model to carry its own automatic fire-fighting system, particularly if there is any fire risk to the environment.

Automatic systems are available, one such system comprises a lightweight plastic tube containing liquefied extinguishant gas. In a fire the plastic tube melts and bursts, releasing the extinguishant. The system is most effective where the fire and the extinguishant are contained within an enclosed space. A model with a gas turbine installed internally with the usual air intake and jet exhaust is likely to be suitable for protection by this system. Tubes are typically 500 mm long by 8 mm diameter and weigh 30 grammes.

A6.1.2 Grass damage and fire

All grass will be damaged by hot exhaust gas streams but this may not be immediately apparent. If damage has occurred it will be apparent by a yellowing of the affected area a few days after the exposure to the hot gases. It is in everybody's interest that this damage is prevented. A fire-blanket lying behind the gas turbine will provide good protection for the grass. A localised grass fire can be dealt with by smothering with such a glass fibre fire blanket.

It is good practice to employ an external extension duct to provide protection from the hot jet exhaust during starting.

A fire extinguisher should always be taken by the assigned fire-fighter to a model being retrieved after landing.

A6.1.3 Control of Sources of Ignition

Decanting, venting or fuelling of flammable gases must be prohibited within a radius of 50 metres from operating gas turbines or other sources of ignition. In still-air conditions it may be necessary to increase significantly the radius of the protected area because of the heavier than air nature of gaseous fuels which could collect in significant quantities.

A6.1.5 Transport and Storage of Liquid Fuel

Always comply with the instructions displayed at the point of sale. A typical notice contains the instruction:- "Always store and carry petrol or diesel fuels in a properly designed and labelled metal or plastic container which can be securely closed."

The same notice, but in respect of petrol, also warns that it is illegal to store more than 13 litres (3 gallons) of petrol without the consent of the Local Petroleum Licensing Authority. It does not warn that such storage is illegal in the case of diesel fuel.

A6.1.6.1 & A6.1.6.7 Residual Fuel

Loss of control of engines on start-up can be caused by fuel having accumulated in the engine prior to the start. Sealed fuel systems will deliver significant quantities of fuel, because of expansion, if a model is allowed to stand in the sun for a time after refuelling. It is a sensible precaution to tip an engine on end before starting to empty out residual fuel.

On shutting down an engine it is good practice to reverse the fuel pump to remove all fuel in the line between the pump and the engine. Also check that there are no flames still burning within the engine.

A6.2.1 Check Lists

A check list should comprise, but not necessarily be limited to, the following:-

Check prior to running that:-

* The shaft is free turning and the engine emits no unusual noises. (Check by blowing into the air intake).
* Oil levels are correct
* Residual fuel is drained off. (Tip engine to whatever attitude necessary to release all trapped fuel).
* Engine and all associated fittings are secure.
* Serviceable fire extinguisher and trained operator are in position.
* Starter gas supply is of adequate pressure.
* Starter batteries are adequately charged.
* Loose foreign objects are removed. (FOD Check)

Following the appropriate starting sequence, when the engine is stopped perform the following:-

* Isolate the fuel supply.
* Listen for unusual noises during the run-down.
* Ensure that all flames are extinguished.

A6.2.6 Engine protection

Engines under development should always be monitored by speed and temperature sensors to prevent maximum safe values being exceeded. Maximum allowable speed should be approached with caution and a means of shutting off the fuel quickly in an emergency must be provided. Electronic protection systems, which will automatically intervene and reduce the fuel flow when maximum parameters are about to be exceeded, can be very useful during development testing. However, electronic sensors can fail so engine development should be directed at removing reliance upon electronic protection systems.

A6.3.3 Danger from the Rotational Plane

If a compressor or turbine of a running engine were to fail and the case of the engine was unable to contain the debris, such debris would be ejected in the plane of rotation of the failed component, i.e. sideways. Therefore no person should be allowed close to the side of a running engine. As the rear of the engine is also a prohibited area because of the heat of the exhaust the only safe area is in front of the engine.

When more than one engine is being operated in close proximity, operators should liaise with each other to arrange that all engines point in the same direction (away from any spectators) and all lie on one line which is at right angles to their rotational axes. All operators should then remain in front of the line of engines.

A7 Maintenance and Service History

By logging all running and maintenance, a detailed history of an engines performance and serviceability will be produced. This will provide valuable information in respect of maintenance intervals. Degradation in performance will be more easily detected and it may prevent the engine being operated in an unsafe state.

A9 Radio Controlled Model Aircraft Pilots Qualifications

A crash involving a gas turbine powered aircraft can have serious consequences because of the risk of fire. Also gas turbine powered aircraft can be capable of high speeds because the thrust does not decrease much with increasing airspeed, unlike those equipped with propellers. These factors combined with other idiosyncrasies, such as throttle lag and high thrust at minimum power, serve to place demands upon an operators competency which may be much higher than those met with propeller equipped aircraft.


Appendix 2
Hazardous Materials


Hydrocarbon Fuels and Oils

There are health hazards associated with fuels and oils and suppliers are bound by law to make health and safety information available to users of such products. It is recommended that copies of the Material Safety Data Sheets are obtained; these can be obtained, for instance, from the garage supplying the products. The data sheets will give information in respect of the acute and chronic health hazards together with first aid and emergency action. To emphasise the importance of obtaining such information the following is an extract from a diesel fuel data sheet in respect of the chronic health hazard:-

"Skin contact over prolonged and repeated periods can lead to defatting of the skin, dermatitis, erythema, oil acne and oil folliculitis. Where occupational and personal hygiene practices have been of a poor standard, warty growths have occurred and these can become cancerous."


Viton Synthetic Rubber

Viton rubber is a fluoroelastomer and if heated beyond 400oC does not burn but decomposes with the formation of HYDROFLUORIC ACID. This acid is extremely corrosive and is almost IMPOSSIBLE to REMOVE once it has contaminated the skin. Any person required to inspect and/or replace any overheated gaskets or seals made from this material should not permit, under any circumstance, contact with the bare skin. VERY NASTY BURNS may occur, which under extreme circumstances could lead to the need for AMPUTATION.

High temperature oil resistant Viton o-rings are capable of operating in temperatures down to -15oC and up to +200oC. The much safer Nitrile o-rings are capable of withstanding temperatures from -40oC to +110oC for long periods with excursions to 135oC . It is strongly advised that Viton 0-rings are not used for any purpose in gas turbine engine construction.


Turbine Oils containing Organophosphates

Special oils, designed for full size gas turbine operation, may contain hazardous chemicals such as organophosphates. Given suitable precautions to avoid skin contact and the breathing of vapours these oils can be used safely. However non-toxic alternatives such as TCW-3 two stroke oil are available and have been used successfully in model gas turbines. Many operators may prefer to use these oils because of their environmentally friendlier properties. If you are in any doubt as to the suitability of these oils for you particular engine you are advised to consult the designer or manufacturer.